Benefits
- High accuracy characteristics over the entire operating temperature range up to 0.08% over the entire pressure measurement range, including the initial section
- High resolution
- High resistance to external factors impact
- Domestic element base
Scope
Systems of surface ships and underwater vehicles.
Principle of Operation
The atmosphere pressure sensor operates based on variations of a resonant vibration frequency of high-quality quartz resonator, which has long-term calibration curve stability under the barometric pressure impact.
Measuring Instruments Type Approval Certificate RU.С.30.018.В No. 59270.
Specifications
|
PDS-A-0.4-S |
PDS-A-6-T |
PDS-A-25-S |
Upper limit of measured absolute pressure (URL), MPa |
0,40 |
6,00 |
25,00 |
Lower limit of measured absolute pressure, MPa |
0,03 |
0,03 |
0,10 |
Maximum allowable pressure, % URL |
125 |
||
Maximum permissible error in the operating temperature range, % URL |
±0,08 (±3,2 hPa) |
±0,08 (±48 hPa) |
±0,08 (±200 hPa) |
Monitored area |
Hydraulic fluid (FHF) or air |
Sea water or air |
Hydraulic fluid (FHF) or air |
Monitored environment temperature range, °C |
from -30 to +50 |
from -30 to +50, from -4 to +32 (sea water) |
from -30 to +50 |
Power supply voltage, V |
27±5 |
||
Current consumption, mA, not more than |
60 |
||
Output interface |
RS-485 |
||
Sampling time, ms, not less than |
800 |
||
Dimensions |
Ø 110х215 |
Ø 110х249 |
|
Weight, kg, not more than |
2,7 |
2,3 |
3,1 |